Electrical data
Lamp wattage 39 W
Line current 0.19 A 
Ignition voltage 4.5 kVp
Operating frequency 0.200…0.240 kHz
System wattage [AGGR] 43.00 W
ECG efficiency 91 %
Input voltage AC 198…264 V
Nominal voltage 220…240 V
Mains frequency 50…60 Hz
Power factor λ 0.95
Inrush current 30 A 
Max. ECG no. on circuit breaker 10 A (B) 15  
Max. ECG no. on circuit breaker 16 A (B) 26  
Max. no. of ECGs on 16A MCB with EBN-OS 65  
Maximum current for mains looping 16 A
Protective conductor current 0.3 mA
U-OUT (working voltage) 250 V
Max. working voltage between LH and LL 250 V
Max. working voltage betw. LL/LH & earth 250 V
Max. capacitance of wire ECG/lamp 120 pF
Dimensions & weight
Length 171.0 mm
Width 83.0 mm
Height 32.0 mm
Mounting hole spacing, length 163.0 mm
Cable cross-section, input side 0.75…2.5 mm²
Cable cross-section, output side 0.75…2.5 mm²
Wire preparation length, input side 10…11 mm
Wire preparation length, output side 10…11 mm
Product weight 285.00 g
Colors & materials
Casing material Plastic
Temperatures & operating conditions
Ambient temperature range -25…+65 °C
Maximum temperature at tc test point 80 °C
Lifespan
ECG lifetime 50000 h 
Additional product data
Design / version With cable clamp
Capabilities
Max. cable length to lamp/LED module 1.5 m
Overheating protection Power reduction and switch off at T > 80 °C at the tc point
Overvoltage protection at 275…300 V 48 h 
Overvoltage protection at 300…320 V 2 h 
Overvoltage protection at 320…350 V 5 min 
ECG reset time > 0.5 s
Cable/wire types, input side NYM-J 3x1.5 / NYM-J 3x2.5 / H05VV-F 3x1.5 / NHXMH-J 3x1.5 mm²
Cable/wire types, output side SIHF-J 3x1.5 / SIHF-J 3x2.5 / SIHSI 3x1.0 mm²
Dimmable No
Restriction on ignition time 20 min
Suitable for fixtures with prot. class I

 

Product benefits

  • Extended terminal section enables mains looping
  • Screw-down cable clamps for reliable strain relief
  • Long reliable life at maximum permitted temperatures
  • Automatic safety shutdown of lamps in the event of a defect or at end of life (EoL)

Areas of application

  • Shop lighting
  • Health and fitness areas (in dry, corrosion-protected place)
  • Effect and accent lighting

Product features

  • Energy Efficiency Index EEI: A2
  • Supply voltage: 220…240 V
  • Line frequency: 50…60 Hz
  • RI suppression: to EN 55015/CISPR 15
  • Safety: to EN 61347-2-12
  • Line harmonics according to EN 61000-3-2
  • Immunity according to EN 61547

Safety advice
Ballast losses and lamp heat radiation can lead to heat accumulation in a completely closed case. Therefore it is necessary to ensure that the temperature at the measuring point t of the ECG does not exceed the maximum value.
Attention!
For safety reasons disconnect the device before replacing the lamp!