PTi 100/220...240 S POWERTRONIC INTELLIGENT S

 

Technical data
Expand
Electrical data
Lamp wattage 97 W
Line current 0.49 A 
Ignition voltage 4.5 kVp
Operating frequency 0.165 kHz
System wattage 106.00 W
ECG efficiency 92 %
Input voltage AC 220…240 V
Input voltage range AC 198…254 V
Mains frequency 50…60 Hz
Power factor λ 0.95  
Inrush current 60 A 
Max. no. of ECGs on circuit breaker 10 A  
Max. no. of ECGs on circuit breaker 16 A  
Max. no. of ECGs on 16A MCB with EBN-OS 20  
Protective conductor current 0.4 mA
U-OUT (working voltage) 250 V
Max. working voltage between LH and LL 250 V
Max. working voltage betw. LL/LH & earth 250 V
Max. capacitance of wire ECG/lamp 120 pF

Dimensions & weight

 
Length 150.0 mm
Width 85.0 mm
Height 31.0 mm
Mounting hole spacing, length 139.0 mm
Mounting hole spacing, width 74.0 mm
Cable cross-section, input side 0.5…2.5 mm²
Cable cross-section, output side 0.5…2.5 mm²
Wire preparation length, input side 10…11 mm
Wire preparation length, output side 10…11 mm
Product weight 350.00 g

Colors & materials

 
Casing material Metal

Temperatures

 
Ambient temperature range -25…+55 °C
Maximum temperature at tc test point 80 °C

Lifespan

 
ECG lifetime 50000 h 

Product benefits

  • Long reliable life at maximum permitted temperatures
  • Compact dimensions and low weight for small luminaire designs
  • Excellent thermal behavior for very high limit temperatures tc and ta
  • Automatic safety shutdown of lamps in the event of a defect or at end of life (EoL)

Areas of application

  • Shop lighting
  • Health and fitness areas (in dry, corrosion-protected place)
  • Effect and accent lighting

Product features

  • Energy Efficiency Index EEI: A2
  • Supply voltage: 220…240 V
  • Line frequency: 50…60 Hz
  • RI suppression: to EN 55015/CISPR 15
  • Safety: to EN 61347-2-12
  • Line harmonics according to EN 61000-3-2
  • Immunity according to EN 61547

Thermal characteristics
Ballast losses and lamp heat radiation can lead to heat accumulation in a completely closed case. Therefore it is necessary to ensure that the temperature at the measuring point tc of the ECG does not exceed the maximum value.
Attention!
For safety reasons disconnect the device before replacing the lamp!
Any conductive material must have a minimum distance of 4 mm to the front of the terminal block.
Installation by qualified electrician only.
Terminals for protective earth not suitable for any through connection.